Family | Wire section without caps | Wire section with caps | Contact features |
|
---|---|---|---|---|
BLZF 3.50 | 0,3÷1,50 mm2 | 0,3÷1 mm2 | Self-locking spring contact |
|
B2L 3.50 | 0,3÷1,00 mm2 | 0,3÷0,5 mm2 | ||
B2CF 3.50 | 0,14÷1,50 mm2 | 0,14÷1,50 mm2 | ||
BLZF 5.08 | 0,3÷2,50 mm2 | 0,3÷2,00 mm2 | ||
BLF 5.00 | 0,2÷2,50 mm2 | 0,3÷2,00 mm2 | ||
BLZ 5.00 | 0,2÷2,50 mm2 | 0,1÷1 mm2 | Screw contact |
|
| MSTB 2.5 MSTBT 2.5 | 0,2-2,5mm2 | 0,25-2,5mm2 |
Connectable conductors | |||
---|---|---|---|
Clamping Range, Sizing link, min. | 0,13 mm2 | Clamping Range, Sizing link, max. | 1,5 mm2 |
AWG Cable Connection Section, min. | AWG 28 | AWG Cable Connection Section, max | AWG 16 |
Outer insulation diameter, max. | 1,5 mm2 | hard, min. H05(07) V-U | 0,2 mm2 |
hard, max. H05(07) V-U | 1,5 mm2 | flexible, min. H05(07) V-K | 0,2 mm2 |
flexible, max. H05(07) V-K | 1,5 mm2 | with terminal in accordance with DIN 46 228/1, min. | 0,2 mm2 |
with terminal in accordance with DIN 46 228/1, max. | 1,5 mm2 | with AEH terminal with collar DIN 46 228/4, min. | 0,2 mm2 |
with AEH terminal with collar DIN 46 228/4, max. | 1 mm2 | Caliber in accordance with EN 60999 a x b; Ø | 2,4 mm x 1,5 mm |
Connectable conductors | |||
---|---|---|---|
Clamping Range, Sizing link, min. | 0,08 mm2 | Clamping Range, Sizing link, max. | 1 mm2 |
AWG Cable Connection Section, min. | AWG 28 | AWG Cable Connection Section, max. | AWG 18 |
hard, min. H05(07) V-U | 0,2 mm2 | hard, max. H05(07) V-U | 1 mm2 |
flexible, min. H05(07) V-K | 0,2 mm2 | flexible, max. H05(07) V-K | 1 mm2 |
with terminal in accordance with DIN 46 228/1, min. | 0,13 mm2 | with terminal in accordance with DIN 46 228/1, max. | 0,34 mm2 |
with AEH terminal with collar DIN 46 228/4, min. | 0,13 mm2 | with AEH terminal with collar DIN 46 228/4, max. | 0,34 mm2 |
Connectable conductors | |||
---|---|---|---|
Clamping Range, Sizing link, min. | 0,14 mm2 | Clamping Range, Sizing link, max. | 1,5 mm2 |
hard, min. H05(07) V-U | 0,14 mm2 | hard, max. H05(07) V-U | 1,5 mm2 |
flexible, min. H05(07) V-K | 0,14 mm2 | flexible, max. H05(07) V-K | 1,5 mm2 |
with terminal in accordance with DIN 46 228/1, min. | 0,14 mm2 | with terminal in accordance with DIN 46 228/1, max. | 1,5 mm2 |
with AEH terminal with collar DIN 46 228/4, min. | 0,14 mm2 | with AEH terminal with collar DIN 46 228/4, max. | 1 mm2 |
Connectable conductors | |||
---|---|---|---|
Clamping Range, Sizing link, min. | 0,13 mm2 | Clamping Range, Sizing link, max. | 3,31 mm2 |
AWG Cable Connection Section, min. | AWG 26 | AWG Cable Connection Section, max | AWG 12 |
hard, min. H05(07) V-U | 0,2 mm2 | hard, max. H05(07) V-U | 2,5 mm2 |
flexible, min. H05(07) V-K | 0,2 mm2 | flexible, max. H05(07) V-K | 2,5 mm2 |
with terminal in accordance with DIN 46 228/1, min. | 0,2 mm2 | with terminal in accordance with DIN 46 228/1, max. | 2,5 mm2 |
with AEH terminal with collar DIN 46 228/4, min. | 0,2 mm2 | with AEH terminal with collar DIN 46 228/4, max. | 2,5 mm2 |
Caliber in accordance with EN 60999 a x b; Ø | 2,8 mm x 2,0 mm |
Rigid conductor section min. | 0,2 mm2 |
Rigid conductor section max. | 2,5 mm2 |
Flexible conductor section min. | 0,2 mm2 |
Flexible conductor section max. | 2,5 mm2 |
Flexible conductor section with cable lug without plastic collar min. | 0,25 mm2 |
Flexible conductor section with cable lug without plastic collar max. | 2,5 mm2 |
Flexible conductor section with cable lug with plastic collar min. | 0,25 mm2 |
Flexible conductor section with cable lug with plastic collar max. | 2,5 mm2 |
Conductor cross section AWG min. | 24 |
Conductor cross section AWG min. | 12 |
2 wires same diameter, hard min. | 0,2 mm2 |
2 wires same diameter, hard max. | 1 mm2 |
2 wires same diameter, flexible min. | 0,2 mm2 |
2 wires same diameter, flexible max. | 1,5 mm2 |
2 conductors with same diameter, flexible with AEH without plastic collar min. | 0,25 mm2 |
2 conductors with same diameter, flexible with AEH without plastic collar max. | 1 mm2 |
2 conductors with same diameter, flexible with TWIN-AEH with plastic collar min. | 0,5 mm2 |
2 conductors with same diameter, flexible with TWIN-AEH with plastic collar max. | 1,5 mm2 |
AWG according with UL/CUL min. | 30 |
AWG according with UL/CUL max. | 12 |
For most safer wiring, we recommend the use of Caps |
---|
Wire section | Plunger section | Brand | Model |
---|---|---|---|
0,1÷0,3 mm2 | 0,95 mm2 | Cembre | PKE 308 |
0,3÷0,5 mm2 | 1,32 mm2 | Cembre | PKE 508 |
BM | BM00601 | ||
1 mm2 | 2,5mm2 | BM00603 | PK 108 |
BM | BM00603 |
Model: “Cembre ND#4 cod. 2590086”
Flat blade Screwdriver according to DIN 5264-A.
A = 0,6mm
B = 2,5mm max
C = 7 mm min
Flat blade Screwdriver According to DIN 5264. Tightening torque: 0,4 ÷ 0,5 Nm.
A = 0,6mm
B = 3,5mm
Discover the copper wire for 10mm | |
Insert the plunger and tighten it with the appropriate clamp | |
a) Insert the screwdriver without rotate it b) Insert the plunger into the clamp |
|
Remove the screwdriver |
Rigid wire | |
With plunger | |
Flexible wire |
The plunger to be used with the B2CF connectors must be long at least 12mm |
---|