Differences
This shows you the differences between two versions of the page.
en:lib:mdl:mdl-h-cnanimp-020 [2016/07/27 17:08] – created qem103 | en:lib:mdl:mdl-h-cnanimp-020 [2019/08/29 17:01] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | /*=== 2 potentiometer, | ||
+ | ^ CN18 ^Terminal^Simbol^Description^Address^ | ||
+ | | {{connettori: | ||
+ | |:::| 2 | IA1 |Analog input 1|3.AI01| | ||
+ | |:::| 3 | SEL1V |Voltmetric 0÷10V analog input selector 1 [(If you connect this terminal on the GAI, the input work as voltmetric 0÷10V)]| | | ||
+ | |:::| 4 | SEL1C |Amperometric 0÷20mA analog input selector 1 [(If you connect this terminal in the GAI, the inputs work as amprometric 0÷20mA)]| | | ||
+ | |:::| 5 | GAI |Analog inputs common| | | ||
+ | |:::| 6 | IA2 |Analog input 2| 3.AI02 | ||
+ | |:::| 7 | SEL2V |Voltmetric 0÷10V analog input selector 2 [(#1)]| | | ||
+ | |:::| 8 | SEL2C |Amperometric 0÷20mA analog input selector 2 [(#2)]| | | ||
+ | |:::| 9 | VREF |Reference voltage| | | ||
+ | ~~REFNOTES~~ |