:tip:The electrical features are given in section Electrical features.
The connection examples are provided in section Connection examples

.

@cnna@ >TerminalSimbolDescription Address
1A +24V dc output 1)
2A PHA1 Phase A Counter 1
PNP / Push-Pull2)
@slot@.INP@ina@@slot@.CNT@cnta@
3A PHB1 Phase B @slot@.INP@inb@
4A Z1 Z 1.INT@inta@
5A 0V Counter inputs common
6A 0V
7A 0V
1B +24V dc output3)
2B PHA1+ + PHA Counter 1
Line Driver
@slot@.INP@ina@ @slot@.CNT@cnta@
3B PHB1+ + PHB@slot@.INP@inb@
4B Z1+ + Z 1.INT@inta@
5B PHA1- - PHA
6B PHB1- - PHB
7B Z1- - Z

1), 3) Can be used to power the encoder. See the Connection examples.
2) Configuration type counter PNP/Push-Pull:
5B terminal : to connect at 5A terminal
6B terminal: to connect at 6A terminal
7B terminal: to connect at 7A terminal
@cnnb@ TerminalSimbolDescription Address
1A +24V dc output1)
2A PHA2 Phase A Conteggio 2
PNP / Push-Pull2)
@slot@.INP@inc@@slot@.CNT@cntb@
3A PHB2 Phase B @slot@.INP@ind@
4A Z2 Z 1.INT@intb@
5A 0V Counter inputs common
6A 0V
7A 0V
1B +24V dc output3)
2B PHA2+ + PHA Counter 2
Line Driver
@slot@.INP@inc@ @slot@.CNT@cntb@
3B PHB2+ + PHB @slot@.INP@ind@
4B Z2+ + Z 1.INT@intb@
5B PHA2- - PHA
6B PHB2- - PHB
7B Z2- - Z

1), 3) Can be used to power the encoder. See the Connection examples.
2) Configuration type counter PNP/Push-Pull:
5B terminal : to connect at 5A terminal
6B terminal: to connect at 6A terminal
7B terminal: to connect at 7A terminal