Differences
This shows you the differences between two versions of the page.
| Both sides previous revision Previous revision Next revision | Previous revision | ||
| en:lib:tpl:tpl-h-cnstep-020 [2015/05/05 16:51] – documentazione | en:lib:tpl:tpl-h-cnstep-020 [2019/08/29 17:01] (current) – external edit 127.0.0.1 | ||
|---|---|---|---|
| Line 1: | Line 1: | ||
| + | /*=== 2 uscite STEP-DIREZIONE ===*/ | ||
| + | === Connector === | ||
| + | |||
| + | ^ @cnn@ ^Terminal^Symbol^Description^^Address^ | ||
| + | | {{connettori: | ||
| + | |:::| 2A | DIR1+ |Output DIRECTION 1|**Push-Pull | ||
| + | |:::| 3A | STEP1+ | ||
| + | |:::| 4A | DIR2+ |Output DIRECTION 2|::: | ||
| + | |:::| 5A | STEP2+ | ||
| + | |:::| 6A | 0V |Common for stepper outputs||| | ||
| + | |:::| 1B | VD1 |Internal bridge 1A -1B||| | ||
| + | |:::| 2B | DIR1- |Complementary output DIRECTION 1|Complementary outputs for use in drives with **Line-Driver** inputs| | ||
| + | |:::| 3B | STEP1- | ||
| + | |:::| 4B | DIR2- |Complementary output DIRECTION 2|:::| | | ||
| + | |:::| 5B | STEP2- | ||
| + | |:::| 6B | 0V |Common for stepper outputs||| | ||
| + | |||
| + | === Outputs STEP-DIRECTION voltage setting === | ||
| + | By placing one of several jumpers JP5, JP6 and JP7, you can choose Nominal Operating Voltage of STEP and DIRECTION outputs. | ||
| + | |||
| + | ^: | ||
| + | . | ||
| + | | ^ jumper\\ name ^ Setting | ||
| + | | {{ : | ||
| + | | ::: | JP6 | ||
| + | | ::: | JP7 | ||
| + | |||