RD_PAR ( Read Device Parameter )

Function name RDPAR_010
Function version 1.0
Function state OBSOLETA
Compatibility with IEC61131-3 not compatible

Graphic symbol :

Input / Output :

Name Belonging Group Access Types of data Description
ON Left Power Flow Activation data writing ad rising edge
Name Device name Nome del device
Parameter Parameter device R , RW F , B , W , L , S Device parameter
Value Normal W , RW F , B , W , L , S Value read in the device parameter
Q Right Power Flow Resulting state of the elaboration function

Description :

The function block RD_PAR allows to read a value in a parameter of a specified device