![]() | The following table shows the mapping of the MODBUS protocol WORD that you can be read. All the WORD must be read with the “Holding Registers”. |
---|
Modbus Word Address | HA548.04 parameter description | HA548.04 Address | Acces type R/W |
---|---|---|---|
0001 | Progressive number of refresh cycles | n.d. | R |
0002 | Error numbers of the comunication toward the HA548.04 | n.d. | R |
0003 | Co1 Torqe threshold | FC28 | R/W |
0004 0005 | Basic differential speed (dn 0) | FC2A | R/W |
0006 | Co 2 Torque threshold | FC2E | R/W |
0007 0008 | Differential modulation speed (dn 1) | FC30 | R/W |
0009 | Co 2 Torque threshold | FC34 | R/W |
0010 0011 | Safety differential speed (dn 2) | FC36 | R/W |
0012 | Calculated torque of the screw | FC4E | R |
0013 | Temperature reading to the analog input IA2 | FC50 | R |
0014 0015 | Absolute differential ratio cylinder / screw (long) | FC52 | R |
0016 0017 | Screw speed | FC56 | R |
0018 0019 | Cylinder speed | FC5A | R |
0020 | Couple read to the analog input IA1 | FC5E | R |
0021 | Torque for screw torque calculation | FC60 | R |
0022 | Torque differential for predictive calculation | FC62 | R |
0023 | Couple preditive purposes | FC64 | R |
0024 0025 | Adjusting differential speed set point | FC66 | R |
0026 | Inputs state | FC6A | R |
0027 | Outputs state | FC6C | R |
0028 | |||
0029 | |||
0030 | |||
0031 | |||
0032 |
The default settings is of the MODBUS/RTU module is:
![]() | Accepted modbus requests | |
---|---|---|
Type request | Description | |
3 | Read Holding Register | |
6 | Write Single Holding Register | |
16 | Write Multiple Holding Register |
Enter to the HA548.04 setup and to set the following parameters:
Code | Description | Value |
---|---|---|
rS | RS 485 Enable | 1 |
br | RS 485 Speed transmission | 9600 |
db | Number of the data bits | 8 |
Sb | Number of the stop bits | 1 |
PA | Paruty bit | 0 |
rc | Delay of the character transmission | 5 |
CI | Address code | 1 |
The 4 leds L1, L2, L3, L4 shows the diagnostic:
![]() | For reset the communication errors, press the RESET button |
---|
To test the modbus functionality on the PC, you must use a program “Modbus RTU Master”.
You can use the ModScan32 program of WinTech (www.win-tech.com)
![]() | Connect properly the USER port (CN2 pins 4A, 5A, 5B) to the serial port of the PC, and then set the dips SW2.1-5 OFF e SW2.6 ON. |
---|
Press to menù Connection → Connect:
![]() | Length must not exceed the value of 32, otherwise it must be done a reboot of the instrument. |
---|