en:strumenti:qmoveplus:j1p44:p1p44f-010:mce_p1p44f-010 [2021/04/06 18:09] – [Table] qem103en:strumenti:qmoveplus:j1p44:p1p44f-010:mce_p1p44f-010 [2021/04/06 18:22] – [2.3.6.2 CN5] qem103
Line 330: Line 330:
 | {{:strumenti:moduli:rmc1s:dip-6-vert.png?70}}  | //Selecting the Transmission Speed of the Canbus//    |  1          |  OFF       | | {{:strumenti:moduli:rmc1s:dip-6-vert.png?70}}  | //Selecting the Transmission Speed of the Canbus//    |  1          |  OFF       |
 | :::                                            | :::                                                    2          |  ON        | | :::                                            | :::                                                    2          |  ON        |
-| :::                                            | :::                                                    Baud-Rate  |  1Mb       |+| :::                                            | :::                                                    Baud-Rate  |  500Kb     |
 | :::                                            | //Selecting the address of the Canbus slave module//  |  3          |  ON        | | :::                                            | //Selecting the address of the Canbus slave module//  |  3          |  ON        |
 | :::                                            | :::                                                    4          |  OFF       | | :::                                            | :::                                                    4          |  OFF       |
Line 579: Line 579:
  
 ^  **SW2**                                                                                              N. DIP      Function  ^ ^  **SW2**                                                                                              N. DIP      Function  ^
-| {{:strumenti:moduli:rmc1s:dip-6-vert.png?70}}  | //Selecting the Transmission Speed of the Canbus//    |  1          |  ON        |+| {{:strumenti:moduli:rmc1s:dip-6-vert.png?70}}  | //Selecting the Transmission Speed of the Canbus//    |  1          |  OFF       |
 | :::                                            | :::                                                    2          |  ON        | | :::                                            | :::                                                    2          |  ON        |
-| :::                                            | :::                                                    Baud-Rate  |  1Mb       |+| :::                                            | :::                                                    Baud-Rate  |  500Kb     |
 | :::                                            | //Selecting the address of the Canbus slave module//  |  3          |  OFF       | | :::                                            | //Selecting the address of the Canbus slave module//  |  3          |  OFF       |
 | :::                                            | :::                                                    4          |  ON        | | :::                                            | :::                                                    4          |  ON        |
Line 602: Line 602:
 | :::                                                2 (35)        I68  | **Limit switch**            **H Axis**                                  | Forward    NC  | :::  | | :::                                                2 (35)        I68  | **Limit switch**            **H Axis**                                  | Forward    NC  | :::  |
 | :::                                                3 (36)        I69  | :::                        | :::                                          | Backward [(If the H-Axis **is NOT present** (//PH-02// = 0) keep the input active)]  | :::  | :::  | | :::                                                3 (36)        I69  | :::                        | :::                                          | Backward [(If the H-Axis **is NOT present** (//PH-02// = 0) keep the input active)]  | :::  | :::  |
-| :::                                                4 (37)        I70  | //Available//                                                                       |||    |  -   |+| :::                                                4 (37)        I70  | **Pressure switch**         **W and H axes**                            Connect in parallel\\ If active, the W or H axes can be moved |  NO   |  -   |
 | :::                                                5 (38)        I71  | //Available//                                                                       |||  -    -   | | :::                                                5 (38)        I71  | //Available//                                                                       |||  -    -   |
 | :::                                                6 (39)        I72  | **45° dowel pins**         | Dowel pins multiple W position 45° inserted             ||  NO  |  C   | | :::                                                6 (39)        I72  | **45° dowel pins**         | Dowel pins multiple W position 45° inserted             ||  NO  |  C   |
Line 621: Line 621:
 == - NPN logic connections example == == - NPN logic connections example ==
  
-{{:strumenti:qmoveplus:j1p44:p1p44f-010:rmc1s_2_cn6_in_npn_01.png?650|}}+{{:strumenti:qmoveplus:j1p44:p1p44f-010:rmc1s_2_cn6_in_npn_01.png?680|}}
  
 == - PNP logic connections example == == - PNP logic connections example ==
  
-{{:strumenti:qmoveplus:j1p44:p1p44f-010:rmc1s_2_cn6_in_pnp_01.png?650|}}+{{:strumenti:qmoveplus:j1p44:p1p44f-010:rmc1s_2_cn6_in_pnp_01.png?680|}}
  
 <WRAP leftalign round tip 60%> <WRAP leftalign round tip 60%>
Line 765: Line 765:
 | :::                                                8 (29)        O61  | **Slowdown**                                  |  **H Axis**                                                          ||  OFF  | | :::                                                8 (29)        O61  | **Slowdown**                                  |  **H Axis**                                                          ||  OFF  |
 | :::                                                9 (30)        O62  | **Alarm 2**                                   | Activates with the O2 **Alarm** output                              ||  :::   | | :::                                                9 (30)        O62  | **Alarm 2**                                   | Activates with the O2 **Alarm** output                              ||  :::   |
-| :::                                                10 (31)      |  O63  | //Available//                                                                                                          |||     |+| :::                                                10 (31)      |  O63  | **Hydraulic brake control unit W and H Axes**                                                                                                          It activates to extract the wedges and remains active during the movement of the axes  ||  :::    |
 | :::                                                11 (32)      |  O64  | //Available//                                                                                                          |||  -    | | :::                                                11 (32)      |  O64  | //Available//                                                                                                          |||  -    |
 | :::                                                12 (33)      |  V-   | Input of Power Supply outputs (0V dc)                                                                                    |||       | | :::                                                12 (33)      |  V-   | Input of Power Supply outputs (0V dc)                                                                                    |||       |