Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:strumenti:qmoveplus:j1p44:p1p44f-010:mdi_p1p44f-010 [2021/04/21 18:15] – [1.1 Release] qem103 | en:strumenti:qmoveplus:j1p44:p1p44f-010:mdi_p1p44f-010 [2021/04/22 12:45] (current) – [6.4 Hydraulic brake operation (wedges) W and H axes] qem103 | ||
---|---|---|---|
Line 187: | Line 187: | ||
| **PG-32** : OFF LUBRICATION TIMER | min | 0 | 0 - 9999 | Timer waiting between activations of lubrication output **O58**. | | **PG-32** : OFF LUBRICATION TIMER | min | 0 | 0 - 9999 | Timer waiting between activations of lubrication output **O58**. | ||
| **PG-33** : USING X-AXIS POTENZIOMETERS | | **PG-33** : USING X-AXIS POTENZIOMETERS | ||
+ | | **PG-34** : HYDRAULIC BRAKE ENABLE W AND H AXES | - | 0 | 0 - 1 | **0**: disable\\ **1**: enable\\ //Note: in case of stop or emergency the control unit turns off and the brake (wedges) goes to block the axis.// [(If **the I70 Pressure switch input** is active, the axes can move)] | ||
+ | | **PG-35** : DISK/WATER SHUTDOWN AT THE END OF CUTTING | ||
+ | | **PG-36** : HARDWARE BIT | - | 1 | 0 - 1 | **0**: 16 bit (01 and 02 hardware release)\\ **1**: 12 bit (03 hardware release onwards) | ||
Line 679: | Line 682: | ||
< | < | ||
+ | |||
+ | ===== - Hydraulic brake operation (wedges) W and H axes ===== | ||
+ | |||
+ | Active function with parameter //PG-34// = 1. Operating sequence: | ||
+ | |||
+ | - Before handling the W or H axes, the **O63** output of the hydraulic control unit is activated | ||
+ | - The Hydraulic brakes (wedges) are portrayed from the resting position (normally pushed by a spring in the axle locking seat) | ||
+ | - When wedges are fully portrayed, they activate the input **I70** | ||
+ | - The W or H axes move | ||
+ | |||
+ | {{: | ||
===== - Backlash recovery ===== | ===== - Backlash recovery ===== |