Line 187: Line 187:
 | **PG-32** : OFF LUBRICATION TIMER                                                                                                                                                          | min           | 0                | 0 - 9999       | Timer waiting between activations of lubrication output **O58**.                                                                                                                                                                            | | **PG-32** : OFF LUBRICATION TIMER                                                                                                                                                          | min           | 0                | 0 - 9999       | Timer waiting between activations of lubrication output **O58**.                                                                                                                                                                            |
 | **PG-33** : USING X-AXIS POTENZIOMETERS                                                                                                                                                    | -             | 0                | 0 - 1          | **0**: the potentiometers are always active;\\ **1**: the potentiometers are used only when the X-axis is cutting                                                                                                                           | | **PG-33** : USING X-AXIS POTENZIOMETERS                                                                                                                                                    | -             | 0                | 0 - 1          | **0**: the potentiometers are always active;\\ **1**: the potentiometers are used only when the X-axis is cutting                                                                                                                           |
 +| **PG-34** : HYDRAULIC BRAKE ENABLE W AND H AXES                                                                                                                                                            | -             | 0                | 0 - 1          | **0**: disable\\ **1**: enable\\ //Note: in case of stop or emergency the control unit turns off and the brake (wedges) goes to block the axis.// [(If **the I70 Pressure switch input** is active, the axes can move)]                                                             |
 +| **PG-35** : DISK/WATER SHUTDOWN AT THE END OF CUTTING                                                                                                                                                       | -             | 0                | 0 - 1          | **0**: disable (to maintain backward compatibility with old versions)\\ **1**: disable\\ //When this function is enable, works both at the end of a single cut and at the end of a work schedule//                                                                                                                                                                                     |
 +| **PG-36** : HARDWARE BIT                                                                                                                                                                                        | -             | 1                | 0 - 1          | **0**: 16 bit (01 and 02 hardware release)\\ **1**: 12 bit (03 hardware release onwards)                                                                                                                                                                                                   |
  
  
Line 679: Line 682:
  
 <html><pagebreak /></html> <html><pagebreak /></html>
 +
 +===== - Hydraulic brake operation (wedges) W and H axes =====
 +
 +Active function with parameter //PG-34// = 1. Operating sequence:
 +
 +  - Before handling the W or H axes, the **O63** output of the hydraulic control unit is activated
 +  - The Hydraulic brakes (wedges) are portrayed from the resting position (normally pushed by a spring in the axle locking seat)
 +  - When wedges are fully portrayed, they activate the input **I70**
 +  - The W or H axes move
 +
 +{{:strumenti:qmoveplus:j1p44:p1p44f-010:wh_brake.png?400}}
  