 +====== Specialization card 1MG5F rel.01 ======
  
 +{{strumenti:qmoveplus:j1k31:j1k31_1mg5f_01.png?nolink&600|Vista posteriore SLOT 3 - Scheda 1MG5F}}
 +
 +====== Informations ======
 +
 +<WRAP center round box 90%>
 +| {{:varie:logo_qem_documentazione.png?200&direct}}                                                                                                                  |||||
 +^ Document:                                         | **MIM1MG5F01**                                                                                            ||||
 +^ Description:                                       | Manuale di installazione e manutenzione                                                                        ||||
 +^ Editor:                                         | Riccardo Furlato                                                                                               ||||
 +^ Approver                                        | Gabriele Bazzi                                                                                                 ||||
 +^ Link:                                              | http://www.qem.eu/doku/doku.php/en/strumenti/qmoveplus/mim1mg5f01                                      ||||
 +^ Language:                                            | English                                                                                                       ||||
 +|                                                                                                                                                                    |||||
 +^ Document release                                  ^ Hardware release                                                            ^ Description    ^ Note  ^ Date        ^
 +|  01                                                |  01                                                                         | New manual  |       | 10/12/2014  |
 +
 +
 +</WRAP>
 +
 +<html><pagebreak /></html>
 +
 +====== - Description ======
 +The **1MG5F** specialization card for the Qmove+ series.
 +
 +===== - Equipment =====
 +
 +|{{Icone:Icona_digital-in.png?nolink&50}}|16 standard digital inputs (+8 alternative inputs to 4 counters)|
 +|{{Icone:Icona_fast-in.png?nolink&50}}|2 rapid digital inputs|
 +|{{Icone:Icona_cnt-abz.png?nolink&50}}|4 bidirectional counters|
 +|{{icone:icona_encoder-ssi.png?nolink&50}}|2 SSI absolute counters|
 +|{{Icone:Icona_analog-in.png?nolink&50}}|4 analog inputs|
 +|{{Icone:Icona_digital-out.png?nolink&50}}|16 digital outputs|
 +|{{Icone:Icona_analog-out.png?nolink&50}}|4 analog outputs|
 +|{{Icone:Icona_stepper-out.png?nolink&50}}|4 step-direction outputs|
 +
 +~~REFNOTES~~
 +
 +<html><pagebreak /></html>
 +
 +====== - Connectors ======
 +
 +===== - Digital inputs =====
 +==== - 16 standard digital inputs + 2 rapid digital inputs ====
 +{{page>en:lib:mdl:mdl-h-cndiginp-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - 4 bidirectional counter inputs 200KHz ====
 +
 +{{page>en:lib:mdl:mdl-h-cncount-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - 2 SSI absolute counter ====
 +
 +{{page>en:lib:mdl:mdl-h-cncntssi-010}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Ingressi analogici =====
 +
 +==== - 4 potentiometric, voltmetric and amperometric analog inputs 12bit ====
 +
 +{{page>en:lib:mdl:mdl-h-cnaninp-030}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Digital outputs =====
 +==== - 16 protected digital outputs ====
 +
 +{{page>en:lib:mdl:mdl-h-cndigout-030}}
 +
 +<html><pagebreak /></html>
 +
 +==== - 4 STEP-DIRECTION outputs ====
 +
 +{{page>en:lib:mdl:mdl-h-cnstep-010}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Uscite analogiche =====
 +==== - 4 analog outputs +/-10V, 16bit ====
 +
 +{{page>en:lib:mdl:mdl-h-cnanout-010}}
 +
 +<html><pagebreak /></html>
 +
 +====== - Connection examples ======
 +
 +===== - Digital inputs =====
 +
 +{{schemi:cbl_in-standard_01.png?nolink&450|Standard and rapid PNP digital inputs connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Line Driver counter inputs =====
 +
 +{{schemi:cbl_conteggio-ld_01.png?nolink&400|Line Driver counter inputs connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - PNP / Push Pull counter inputs =====
 +
 +{{schemi:cbl_conteggio-pp-pnp_01.png?nolink&400|PNP / Push Pull counter input connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Voltmetric and amperometric analog inputs =====
 +
 +{{schemi:cbl_in-volt-amp_01.png?nolink&400|Voltmetric and amperometric analog inputs connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Voltmetric and potentiometric analog inputs =====
 +
 +{{schemi:cbl_in-volt-pot_01.png?nolink&400|Voltmetric and potentiometric analog input connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Protected digital outputs =====
 +
 +{{schemi:cbl_out-protette_02.png?nolink&400|Protected digital output connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - STEP - DIRECTION outputs =====
 +
 +{{schemi:cbl_stepper_pp-ld_01.png?nolink&450|STEP - DIRECTION output connection example}}
 +
 +<html><pagebreak /></html>
 +
 +===== - Analog outputs =====
 +
 +{{schemi:cbl_out-analogic_01.png?nolink&400|Analog output connection example}}
 +
 +<html><pagebreak /></html>
 +
 +====== - Electrical features ======
 +The following are the electrical hardware features.\\
 +The maximum and minimum frequency values and actual acquisition times, can still depend on any additional software filters, see the system variable “QMOVE:sys004”.
 +
 +==== - Standard digital inputs ====
 +
 +{{page>en:lib:mdl:mdl-h-cediginp-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Rapid digital inputs ====
 +
 +{{page>en:lib:mdl:mdl-h-cefreq-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Bidirectional digital inputs 200KHz====
 +
 +{{page>en:lib:mdl:mdl-h-cecount-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - SSI absolute counters ====
 +
 +{{page>en:lib:mdl:mdl-h-cessi-010}}
 +
 +<html><pagebreak /></html>
 +==== - Potentiometric analog inputs ====
 +
 +{{page>en:lib:mdl:mdl-h-ceaninp-020}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Voltmetric analog inputs ====
 +
 +{{page>en:lib:mdl:mdl-h-ceaninp-030}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Amperometric analog inputs ====
 +
 +{{page>en:lib:mdl:mdl-h-ceaninp-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Protected digital outputs ====
 +
 +{{page>en:lib:mdl:mdl-h-cedigout-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Stepper outputs ====
 +
 +{{page>en:lib:mdl:mdl-h-cestep-010}}
 +
 +<html><pagebreak /></html>
 +
 +==== - Analog outputs ====
 +
 +{{page>en:lib:mdl:mdl-h-ceanout-010}}