 +====== Reset checksum error procedure on R201A ======
 +
 +The purpose of the following document is to integrate the procedure already described in the Hardware Manual of the [[en:Strumenti:MicroQmove:R201]] to pag. 22.
 +
 +==== R201 instrument normally in operation ====
 +{{:appnote:an018:an018_5.jpg?500&nolink|}}
 +
 +==== QC043 instrument usually in operation ====
 +{{:appnote:an018:an018_2.jpg?450&nolink|}}
 +
 +
 +<html><pagebreak /></html>
 +==== FUNC and BOOT keys ====
 +{{:appnote:an018:an018_12.jpg?600&nolink|}}
 +
 +====System LEDs==== 
 +{{:appnote:an018:an018_11.jpg?600&nolink|}}
 +
 +
 +<html><pagebreak /></html>
 +==== Procedure for error checksum reset of the r201====
 +
 +  * Instrument in error CHECKSUM: led **PWR** fixed, led **ERR** makes two flashes.
 +{{:appnote:an018:an018_8.jpg?600&nolink|}}
 +
 +  * Restart the instrument by pressing and holding the **FUNC** key
 +{{:appnote:an018:an018_7.jpg?300&nolink|}}
 +
 +  * So you enter in the system functions: led **PWR** on and led **L4** on.
 +{{:appnote:an018:an018_9.jpg?600&nolink|}}
 +
 +  * Press the **BOOT** key for 2 seconds.
 +{{:appnote:an018:an018_6.jpg?300&nolink|}}
 +
 +  * Start the error reset procedure: led **PWR** flashes.
 +
 +
 +  * End the error reset procedure and the instrument restarts.
 +
 +
 +  * NOTE: If, to end the **L4** and **ERR** LED lights up fixed manually restart the instrument.
 +{{:appnote:an018:an018_10.jpg?600&nolink|}}
 +
 +  * To the end the R201 instrument return in run state
 +{{:appnote:an018:an018_5.jpg?600&nolink|}}
 +
 +
 +<html><pagebreak /></html>
 +==== Error message checksum from QC043 ====
 +
 +  * If the R201 is in checksum error then  in the QC043 will appear the following screen:
 +{{:appnote:an018:an018_13.jpg?450&nolink|}}
 +
 +  * Press the **F2** key on the panel to continue. 
 +{{:appnote:an018:an018_14.jpg?450&nolink|}}
 +