+ | ^ SW1 ^Dip^DIP settings^^^^Function^ | ||
+ | | {{dip-switch: | ||
+ | |:::| 2 | OFF | ON | OFF | ON |:::| | ||
+ | |:::| | Baud-rate\\ 38400 | Baud-rate\\ 115200 | ||
+ | |:::| |||||| | ||
+ | |:::| 3 | OFF | OFF | ON | ON |Select USER PORT transmission speed| | ||
+ | |:::| 4 | OFF | ON | OFF | ON |:::| | ||
+ | |:::| | Baud-rate\\ 38400 | Baud-rate\\ 115200 | ||
+ | |:::| |||||| | ||
+ | |:::| 5 |CANbus baud-rate selector. See paragraph [[#CANbus baud-rate selector]]||||| | ||
+ | |:::| |||||| | ||
+ | |:::| 6 | OFF || ON ||Select PROG PORT functioning mode| | ||
+ | |:::| |PROG PORT can also be used by SERCOM and MODBUS devices||PROG PORT cannot be used by SERCOM and MODBUS devices||::: | ||
+ | |:::| |||||| | ||
+ | |:::| 7 |CANbus baud-rate selector. See paragraph [[#CANbus baud-rate selector]]||||| | ||
+ | |:::| |||||| | ||
+ | |:::| 8 | OFF || ON ||Select the USER PORT as PROG PORT[(It is possible to use the USER PORT connector as PROG PORT with RS232 electric standard, doing this the mini-USB connector of the PROG PORT is disconnected (Setting USER PORT electric standard). **For this function mode also set dip 6 of SW2 to OFF.**)]| | ||
+ | |:::| |PROG PORT normal||PROG PORT on USER PORT connector||::: | ||
+ | ~~REFNOTES~~ |