en:lib:tpl:tpl-h-cnaninp-022

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

en:lib:tpl:tpl-h-cnaninp-022 [2016/08/01 15:03] – created qem103en:lib:tpl:tpl-h-cnaninp-022 [2019/08/29 17:01] (current) – external edit 127.0.0.1
Line 1: Line 1:
 +/*==== 2 multistandard analog inputs ====*/
 +=== Connector ===
 +^  @cnn@                                       ^ Terminal  ^ Simbol  ^  Description  ^^^  Address    ^
 +^:::                                           ^:::        ^:::        Potentiometric / 0-10V / 0-20mA  ^  Termocouple  ^  PT100  ^:::^
 +|  {{connettori:cnn_8f_p3.5_01.png?80&nolink}}  |  1        |  GAI     | Analog inputs common                                  | -  | -                                                                                                                                                      |
 +| :::                                            2        |  VREF    | Reference volatege [(For potentiometric inputs)]  | -  | -                                                                                                                                                      |
 +| :::                                            3        |  AI1_A   | Analog input 1                                       | -  | A [(A and B cables connected to the resistance, have the same color.\\ In the case of 2-wire PT100 you must make a jumper between A and B.)]  |  @slot@.AI01    |
 +| :::                                            4        |  AI1_B   | -                                         | TC 1 -     | B                                                                                                                                                        | :::            |
 +| :::                                            5        |  AI1_C   | -                                         | TC 1 +     | C                                                                                                                                                        | :::            |
 +| :::                                            6        |  AI2_A   | Analog input 2                      | -                   | A [(#2)]                                                                                                                                                  @slot@.AI02    |
 +| :::                                            7        |  AI2_B   | -                                         | TC 2 -     | B                                                                                                                                                        | :::            |
 +| :::                                            8        |  AI2_C   | -                                         | TC 2 +     | C                                                                                                                                                        | :::            |
 +~~REFNOTES~~
 +
 +=== Analog inputs setting ===
 +
 +|                                                                Num.\\ Dip  ^  Analog input 1                       ||||^  Analog input 2                                  |||||
 +| :::                                                           |:::    ^ PT100      ^ Termocouple  ^ Pot.  ^ 0-10V  ^ 0-20mA  ^ PT100        ^ Termocouple  ^ Pot.  ^ 0-10V  ^ 0-20mA  |
 +|  **@dipb@**\\ {{dip-switch:DIP-8.jpg?nolink&80}}              |  1  |  ON          |  X            OFF  |  OFF    OFF  |  X            X            X    |  X    |  X    |
 +| :::                                                            2  |  OFF          X            ON    ON    |  ON    X[(To set OFF if not use for analog input 1)]            X            X    |  X    |  X    |
 +| :::                                                            3  |  X            X            X    |  X      X    |  ON          |  X            OFF  |  OFF  |  OFF  |
 +| :::                                                            4  |  X[(To set OFF if not use for analog input 2 )]            X            X    |  X      X    |  OFF          X            ON    ON    ON   |
 +| :::                                                            5  |  ON          |  ON          |  OFF  |  OFF    OFF  |  X            X            X    |  X    |  X    |
 +| :::                                                            6  |  OFF          OFF          ON    ON    |  ON    X            X            X    |  X    |  X    |
 +| :::                                                            7  |  OFF          ON          |  X    |  X      X    |  X            X            X    |  X    |  X    |
 +| :::                                                            8  |  X            X            X    |  X      X    |  OFF          ON          |  X    |  X    |  X    |
 +| ||||||||||||
 +|  **@dipa@**\\ {{dip-switch:DIP-4.jpg?nolink&80}}              |  1  |  X            |  X            |  X                |  X      |  X        X            |  X            |  OFF              |  OFF    |  ON      |
 +| :::                                                            2  |  X            |  X            |  X                |  X      |  X        X            |  X            |  OFF              |  ON      OFF     |
 +| :::                                                            3  |  X            |  X            |  OFF              |  OFF    |  ON      |  X            |  X            |  X                |  X      |  X       |
 +| :::                                                            4  |  X            |  X            |  OFF              |  ON      OFF      X            |  X            |  X                |  X      |  X       |
 +<wrap lo>X = setting not significant\\ Pot. = potentiometric type input</wrap>
 +~~REFNOTES~~