en:lib:tpl:tpl-h-cnstep-021

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:lib:tpl:tpl-h-cnstep-021 [2016/11/30 08:33] documentazioneen:lib:tpl:tpl-h-cnstep-021 [2019/08/29 17:01] (current) – external edit 127.0.0.1
Line 1: Line 1:
 +/*=== 2 uscite STEP-DIREZIONE ===*/
 +=== Connector ===
 +
 +^  @cnn@  ^Terminal^Symbol^Description^^Address^
 +|  {{connettori:cnn_6x2fv_p3.5_01.png?nolink&100}} {{connettori:cnn_2x6lr_p3.5_01.png?nolink&110}}  |  1A  |  VD1  |Internal bridge 1A -1B|||
 +|:::|  2A  |  DIR1+  |Output DIRECTION 1|**Push-Pull  Line Driver**|@slot@.PULSE01|
 +|:::|  3A  |  STEP1+  |Output STEP 1|:::|:::|
 +|:::|  4A  |  DIR2+  |Output DIRECTION 2|::: @slot@.PULSE02  |
 +|:::|  5A  |  STEP2+  |Output STEP 2|:::|:::|
 +|:::|  6A  |  0V  |Common for stepper outputs|||
 +|:::|  1B  |  VD1  |Internal bridge 1A -1B|||
 +|:::|  2B  |  DIR1-  |Complementary output DIRECTION 1|Complementary outputs for use in drives with **Line-Driver** inputs|    |
 +|:::|  3B  |  STEP1-  |Complementary output STEP 1|:::| |
 +|:::|  4B  |  DIR2-  |Complementary output DIRECTION 2|:::| |
 +|:::|  5B  |  STEP2-  |Complementary output STEP 2|:::| |
 +|:::|  6B  |  0V  |Common for stepper outputs|||
 +
 +=== Outputs STEP-DIRECTION voltage setting ===
 +By placing one of several jumpers JP5, JP6 and JP7, you can choose Nominal Operating Voltage of STEP and DIRECTION outputs.
 +
 +^:important:^Must be inserted only one jumper at a time\\ If you select one of the two voltage 5V (JP7) or 12V (JP5) terminals 1A and 1B must remain disconnected^
 +.
 +|                                                                        ^ jumper\\ name  ^ Setting  ^ Nominal voltage ^^
 +|  {{ :strumenti:qmoveplus:j1p44:j1p44_stepper-set_01.png?200&nolink }}  |  JP5            INSERTED     | 12V (Voltage supplied by the instrument) |\\ \\ {{:strumenti:qmoveplus:j1p44:j1p44_stepper-set_02.png?direct&300|}}|
 +| :::                                                                    |  JP6            INSERTED     | VD1 (Voltage to be supplied to the terminals 1A or 1B)    |:::|
 +| :::                                                                    |  JP7            INSERTED     | 5V  (Voltage supplied by the instrument) |:::|