 === Read Coil === === Read Coil ===
  
-Read bit function. You want to read the bits of a slave (//idcar//d). Sets the parameter //type// = 1.\\ You must set //addr// to indicate the address of the bit in the slave from which to start reading. The //num// parameter indicates the number of bits that are read. You must to set //tabreg// to indicate the index of the bit in the “data read table” the master from which you want to be written the read bits. The raedings value will be saved in the “data read table”. It is recommended to always meet the following two conditions:\\+Bit read function. You want to read the bits of a slave (//idcar//d). Sets the parameter //type// = 1.\\ You must set //addr// to indicate the address of the bit in the slave from which to start reading. The //num// parameter indicates the number of bits that are read. You must to set //tabreg// to indicate the index of the bit in the “data read table” the master from which you want to be written the read bits. The raedings value will be saved in the “data read table”. It is recommended to always meet the following two conditions:\\
 (//addr// + //num// - 1) <= 512 e (//tabreg// + //num// - 1) <= 512 otherwise the request will fail (reporting by //wcmd//). (//addr// + //num// - 1) <= 512 e (//tabreg// + //num// - 1) <= 512 otherwise the request will fail (reporting by //wcmd//).
  
 === Read Input === === Read Input ===
  
-Bit read function. Si vogliono leggere i bit di un certo slave (//idcard//). La funzione è identica alla “//Read Coil//”. Viene impostato il parametro type = 2.\\ Il significato delle due funzioni si distingue a livello di protocollo MODBUS. Alcuni slave possono mettere a disposizione delle zone di memoria differenti a seconda se i bit letti sono Coil Input. Nel caso di slave Qmove le due richieste hanno lo stesso effetto.+Bit read function. To read the bits of a slave (//idcard//). The function is equal to the “//Read Coil//”. Sets the parameter type = 2.\\ The meaning of the two functions is distinguished at the level of MODBUS protocolSome slave can make available different memory areas depending if the bits are Coil or Input. In the case of slave Qmove the two requests have the same effect.
  
 === Read Holding Register === === Read Holding Register ===
-Funzione di lettura a wordSi vogliono leggere le word di un certo slave (idcard). Viene impostato il parametro //type// = 3.\\ + 
-Bisogna impostare addr per indicare l’indirizzo della word nello slave da cui si intende iniziare a leggereIl parametro num +Word read functionFor reading the word of the slave (idcard). Sets the parameter //type// = 3.\\ 
-indica il numero di word che si intendono leggereBisogna impostare tabreg per indicare l’indice della word nella tabella +You must to set addr to indicate the address of the word in the slave from which to start readingThe num parameter indicates the number of word to be readYou must set tabreg to indicate the index of the word in the read data table” of the master from which you want are writes the read wordsThe read values will be saved in the read data table”. It is recommended to always meet the following two conditions:\\ 
-dei dai letti” del master da cui si vuole che siano scritte le word letteI valori letti verranno salvati nella tabella dei dati letti”. +(addr + num - 1) <= 32 e (tabreg + num - 1) <= 32 otherwise the request will fail (reporting by wcmd).
-Si raccomanda di soddisfare sempre le seguenti due condizioni:\\ +
-(addr + num - 1) <= 32 e (tabreg + num - 1) <= 32 altrimenti la richiesta non potrà essere eseguita (segnalazione mediante +
-wcmd).+
  
 === Read Input Register === === Read Input Register ===
-Funzione di lettura ingressi a word. Si vogliono leggere i bit di un certo slave (idcard). La funzione è identica alla “Read Holding Register”. Viene impostato il parametro type = 4.\\ Il significato delle due funzione si distingue a livello di protocollo MODBUS. Alcuni slave possono mettere a disposizione delle zone di memoria differenti a seconda se le word lette sono Holding o Input. Nel caso di slave Qmove le due richieste hanno lo stesso effetto. 
  
-==== - Richieste di scrittura ====+Word read function. For reading the bit of the slave (idcard). The function is equal to the “Read Holding Register”. sets the parameter type = 4.\\ The meaning of the two functions is distinguished at the level of MODBUS protocol. Some slave can make available different memory areas depending if the read word are Holding or Input. In the case of slave Qmove the two requests have the same effect. 
 + 
 +==== - Write request ====
  
 === Force coil === === Force coil ===
-Funzione di scrittura bitSi vogliono scrivere (forzarebit di un certo slave (//idcard//). Viene impostato il parametro //type// = + 
-5.\\ Bisogna impostare addr per indicare l’indirizzo del bit nello slave in cui si intende scrivereBisogna impostare tabreg +Bit write functionFor writing (forcethe bit of the slave (//idcard//). Sets the parameter //type// = 5.\\ You must set addr to indicate the address of the bit in the slave that you want to writeYou must set tabreg to indicate the index of the bit in the write data table” that contains the value to be written.
-per indicare l’indice del bit nella tabella dei dati da scrivere” in cui è contenuto il valore da scrivere.+
  
 === Force register === === Force register ===