en:software:devices:modbus

Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
Next revisionBoth sides next revision
en:software:devices:modbus [2016/12/21 17:39] – [Read Holding Register] qem103en:software:devices:modbus [2016/12/21 17:45] – [Read Holding Register] qem103
Line 182: Line 182:
 === Read Holding Register === === Read Holding Register ===
  
-Word read function. Si vogliono leggere le word di un certo slave (idcard). Sets the parameter //type// = 3.\\+Word read function. If want read the word of the slave (idcard). Sets the parameter //type// = 3.\\
 You must to set addr to indicate the address of the word in the slave from which to start reading. The num parameter indicates the number of word to be read. You must set tabreg to indicate the index of the word in the “read data table” of the master from which you want are writes the read words. The read values will be saved in the “read data table”. It is recommended to always meet the following two conditions:\\ You must to set addr to indicate the address of the word in the slave from which to start reading. The num parameter indicates the number of word to be read. You must set tabreg to indicate the index of the word in the “read data table” of the master from which you want are writes the read words. The read values will be saved in the “read data table”. It is recommended to always meet the following two conditions:\\
 (addr + num - 1) <= 32 e (tabreg + num - 1) <= 32 otherwise the request will fail (reporting by wcmd). (addr + num - 1) <= 32 e (tabreg + num - 1) <= 32 otherwise the request will fail (reporting by wcmd).
  
 === Read Input Register === === Read Input Register ===
-Funzione di lettura ingressi a wordSi vogliono leggere i bit di un certo slave (idcard). La funzione è identica alla “Read Holding Register”. Viene impostato il parametro type = 4.\\ Il significato delle due funzione si distingue a livello di protocollo MODBUS. Alcuni slave possono mettere a disposizione delle zone di memoria differenti a seconda se le word lette sono Holding Input. Nel caso di slave Qmove le due richieste hanno lo stesso effetto.+ 
 +Word read functionFor reading the bit of the slave (idcard). The function is equal to the “Read Holding Register”. sets the parameter type = 4.\\ The meaning of the two functions is distinguished at the level of MODBUS protocolSome slave can make available different memory areas depending if the read word are Holding or Input. In the case of slave Qmove the two requests have the same effect.
  
 ==== - Richieste di scrittura ==== ==== - Richieste di scrittura ====
  • Last modified: 2020/07/13 14:58