en:software:devices:modbus [2016/12/21 17:54] – [Force register] qem103en:software:devices:modbus [2016/12/22 15:57] – [5.7. Broadcast] qem103
Line 201: Line 201:
  
 === Force multiple coil === === Force multiple coil ===
-Funzione di scrittura bit multipliSi vogliono scrivere (forzarebit di un certo slave (//idcard//). Viene impostato il parametro + 
-//type// = 15.\\ Bisogna impostare addr per indicare l’indirizzo del bit nello slave in cui si intende scrivereSi deve impostare in +Multiples bit write functionFor write (forcethe bit of a slave (//idcard//). Sets the parameter //type// = 15.\\ You must set addr to indicate the address of the bit in the slave that you intend to writeYou must set in num the number of bits to writeYou must set tabreg to indicate the bit index of the data write table” from which to begin the values to be writtenIt is recommended to always meet the following two conditions:\\ 
-num il numero di bit da scrivereBisogna impostare tabreg per indicare l’indice del bit nella tabella dei dati da scrivere +(addr + num - 1) <= 512 e (tabreg + num - 1) <= 512 otherwise the request will fail (reporting by wcmd).
-da cui iniziano i valori da scrivereSi raccomanda di soddisfare sempre le seguenti due condizioni:\\ +
-(addr + num - 1) <= 512 e (tabreg + num - 1) <= 512 altrimenti la richiesta non potrà essere eseguita (segnalazione mediante wcmd).+
  
 === Force multiple register === === Force multiple register ===
-Funzione di scrittura word multiple. Si vogliono scrivere (forzare) le word di un certo slave (//idcard//). Viene impostato il parametro 
-//type// = 16.\\ Bisogna impostare addr per indicare l’indirizzo della word nello slave in cui si intende scrivere. Si deve 
-impostare in num il numero di word da scrivere. Bisogna impostare tabreg per indicare l’indice della word nella “tabella 
-dei dati da scrivere” da cui iniziano i valori da scrivere. Si raccomanda di soddisfare sempre le seguenti due condizioni:\\ 
-(addr + num - 1) <= 32 e (tabreg + num - 1) <= 32 altrimenti la richiesta non potrà essere eseguita (segnalazione mediante wcmd). 
  
-==== - Esempi ====+Multiples word write function. For write (forzare) the word of a slave (//idcard//). Sets the parameter //type// = 16.\\ You must set addr to indicate the address of the word in the slave that you intend to write. You must set in num the number of word to write. You must set tabreg to indicate the index of the word in the “dat write table” from which to begin the values to be written. It is recommended to always meet the following two conditions:\\ 
 +(addr + num - 1) <= 32 e (tabreg + num - 1) <= 32 otherwise the request will fail (reporting by wcmd). 
 + 
 +==== - Examples ====
  
-1) Impostazioni modbus e apertura del canale di comunicazione di tipo seriale+1) Modbus settings and opening of serial communication
 <code QCL> <code QCL>
 modbus.mode = 0                             ; modbus master modbus.mode = 0                             ; modbus master
Line 251: Line 247:
 </code> </code>
  
-3) Lettura del registro input nr.7 dello slave id 67+3) Reading the registry input nr.7 of the slave id 67
 <code QCL> <code QCL>
 modbus.idcard = 67 modbus.idcard = 67
Line 261: Line 257:
 WAIT modbus.st_sended WAIT modbus.st_sended
 IF (modbus.err) IF (modbus.err)
-    CALL ErroreModbus+    CALL ErrorModbus
 ENDIF ENDIF
-slVelocita = modbus.iword7+slSpeed = modbus.iword7
 </code> </code>
  
-4) Lettura dei holding register dal nr.600 al nr.606 dello slave id 8\\ +4) Reading of the holding register from nr.600 to nr.606 of the slave id 8\\ 
-Siccome l’area di scambio dati QCL non supporta l’indirizzo 600, si utilizza il parametro tabreg per salvare i dati letti all’indirizzo 10+The area of QCL data exchange does not support the address 600, you use the tabreg parameter to save the data read at 10 address
 <code QCL> <code QCL>
 modbus.idcard = 8 modbus.idcard = 8
Line 277: Line 273:
 WAIT modbus.st_sended WAIT modbus.st_sended
 IF (modbus.err) IF (modbus.err)
-    CALL ErroreModbus+    CALL ErrorModbus
 ENDIF ENDIF
          
 swTemp1 = modbus.iword10 swTemp1 = modbus.iword10
-slVelocita = modbus.ilong6+slSpeed = modbus.ilong6
 slPosiz = modbus.ilong7 slPosiz = modbus.ilong7
 swTemp1 = modbus.iword15 swTemp1 = modbus.iword15
 </code> </code>
-==== - Schema a blocchi ====+==== - Block diagrams ==== 
 {{:software:devices:modbus:modbus_01.png?nolink400|}} {{:software:devices:modbus:modbus_01.png?nolink400|}}
  
 ==== - Broadcast ==== ==== - Broadcast ====
-Il Broadcast è un messaggio speciale che viene inviato dal Master e viene ricevuto contemporaneamente da tutti gli slave + 
-connessiLa funzionalitá broadcast (idcard = 0) è supportata solamente in modo master e se viene usato un messaggio +The Broadcast is a special message that is sent by the Master and is received simultaneously from all connected slavesThe broadcast function (idcard = 0) is supported only in master mode and if you use a message with type = 5, 6, 15 and 16 (write only). In this mode the st_sended state is activated once ended the transmission and not on receipt of confirmation by the slave. There isn't answer on the slaves to such messagesYou cannot use the SENDSYC command.
-con type = 5, 6, 15 16 (solo scrittura). In questa modalità lo stato st_sended viene attivato appena terminata la trasmissione +
-e non alla ricezione della conferma dallo slave. Infatti non esiste nessuna risposta degli slave per questo tipo di +
-messaggiNon è possibile utilizzare il comando SENDSYC.+
  
 ==== - Identificazione degli Slave ==== ==== - Identificazione degli Slave ====
  • Last modified: 2020/07/13 14:58