Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision | Next revisionBoth sides next revision | ||
en:software:devices:modbus [2016/12/23 16:29] – [5.10.4. Stati] qem103 | en:software:devices:modbus [2016/12/23 16:38] – [5.10.5. Comandi] qem103 | ||
---|---|---|---|
Line 403: | Line 403: | ||
|wcmd|F|0|R|-|**Warning Command**\\ This bit indicates that it did not execute a command because they missing the necessary conditions.| | |wcmd|F|0|R|-|**Warning Command**\\ This bit indicates that it did not execute a command because they missing the necessary conditions.| | ||
- | === - Comandi | + | === - Commands |
- | I comandi a disposizione per gestire il device sono elencati sotto in ordine di priorità decrescente.\\ | + | |
- | Il device esegue tutti i comandi ricevuti entro lo stesso tempo di campionamento iniziando da quello con la priorità maggiore.\\ | + | |
- | Per esempio se il device riceve nello stesso tempo di campionamento i comandi CLOSECOM e OPENCOM, per primo esegue il comando OPENCOM e poi quello di CLOSECOM lasciando perciò la porta di comunicazione chiusa. | + | |
- | ^Nome^D^R^A^Condizioni^Descrizione^ | + | The available commands to manage the device are listed below in descending order of priority.\\ |
- | |SEND|-|-|-|mode = 0\\ 0 < num <= 128\\ st_sended = 1\\ st_opencom = 1|**Sended**\\ | + | The device executes all commands received within the same sampling time starting from the one with the highest priority.\\ |
- | |SENDSYC|-|-|-|mode = 0\\ 0 < num <= 128\\ st_sended = 1\\ st_opencom = 1|**Send synchronize**\\ | + | For example if the device receives the same sampling time CLOSECOM and OPENCOM commands, first run the OPENCOM command and then to CLOSECOM leaving therefore the communication port closed. |
- | |READSTYPE|-|-|-|mode = 0\\ st_sended = 1\\ st_opencom = 1|**Read slave type**\\ | + | |
- | |CLRWDATA|-|-|-|-|**Clear Warning Data**\\ | + | ^Name^D^R^A^Conditions^Description^ |
- | |CLRWCMD|-|-|-|-|**Clear Warning Command**\\ | + | |SEND|-|-|-|mode = 0\\ 0 < num <= 128\\ st_sended = 1\\ st_opencom = 1|**Sended**\\ |
- | |OPENCOM|-|-|-|st_opencom = 0|**Open Serial communication**\ | + | |SENDSYC|-|-|-|mode = 0\\ 0 < num <= 128\\ st_sended = 1\\ st_opencom = 1|**Send synchronize**\\ |
- | |CLOSECOM|-|-|-|-|**Close Serial communication**\\ | + | |READSTYPE|-|-|-|mode = 0\\ st_sended = 1\\ st_opencom = 1|**Read slave type**\\ |
+ | |CLRWDATA|-|-|-|-|**Clear Warning Data**\\ | ||
+ | |CLRWCMD|-|-|-|-|**Clear Warning Command**\\ | ||
+ | |OPENCOM|-|-|-|st_opencom = 0|**Open Serial communication**\ | ||
+ | |CLOSECOM|-|-|-|-|**Close Serial communication**\\ | ||