 |serr|B|0|R/W|-|**Serial Errors**\\ Indicates if errors occurred in serial communication.\\ The parameter is updated for each error encountered. The value persists until a subsequent error or to a writing on the same with the QCL.\\ **0** = no errors,\\ **1** = parity error,\\ **2** = framing error,\\ **3** = overrun error.| |serr|B|0|R/W|-|**Serial Errors**\\ Indicates if errors occurred in serial communication.\\ The parameter is updated for each error encountered. The value persists until a subsequent error or to a writing on the same with the QCL.\\ **0** = no errors,\\ **1** = parity error,\\ **2** = framing error,\\ **3** = overrun error.|
  
-=== - Stati === +=== - States === 
-^Nome^D^R^A^CondizioniDescrizione+ 
-|st_msgrx|F|0|R||-|**Message received**\\ Stato utilizzato solo in modalitá slave. Indica che un messagio del master ha eseguito una scrittura nell’area scambio dati QCL. Lo stato viene resettato con il comando RECEIVED.| +^Name^D^R^A^Conditions^Description
-|st_opencom|F|0|R|-|**Open communication port**\\ L'attivazione indica che il device sta impegnando la porta di comunicazione serialePer settare questo stato usare il comando OPENCOM, per resettarlo CLOSECOM.| +|st_msgrx|F|0|R|-|**Message received**\\ State used only in slave modeIndicates that a message from the master has executed a write in the QCL data exchange areaThe state is reset with the RECEIVED command.| 
-|wdata|F|0|R|-|**Warning Data**\\ Questo bit segnala che è stato tentato un inserimento di un valore non valido in un parametro.| +|st_opencom|F|0|R|-|**Open communication port**\\ Activation indicates that the device is working with the serial communications portTo set this state use the OPENCOM commandfor reset use CLOSECOM.| 
-|wcmd|F|0|R|-|**Warning Command**\\ Questo bit segnala che è non è stato eseguito un comando perchè mancano le condizioni necessarie.|+|wdata|F|0|R|-|**Warning Data**\\ This bit indicates that an attempt was made to insert an invalid value in a parameter.| 
 +|wcmd|F|0|R|-|**Warning Command**\\ This bit indicates that it did not execute a command because they lack the necessary conditions.|
  