+ | ====== - P1R11FA10 - 001 : User manual ====== | ||
+ | ===== - MODBUS mapping ===== | ||
+ | ^:info:^The following table shows the mapping of the MODBUS protocol WORD that you can be read.\\ All the WORD must be read with the “Holding Registers”.^ | ||
+ | |||
+ | ^ Modbus\\ Word\\ Address | ||
+ | | 0001 |Progressive number of refresh cycles| | ||
+ | | 0002 |Error numbers of the comunication toward the HA548.04| | ||
+ | | 0003 |Co1 Torqe threshold| | ||
+ | | 0004\\ 0005 |Basic differential speed (dn 0)| FC2A | R/W | | ||
+ | | 0006 |Co 2 Torque threshold| | ||
+ | | 0007\\ 0008 |Differential modulation speed (dn 1)| FC30 | R/W | | ||
+ | | 0009 |Co 2 Torque threshold| | ||
+ | | 0010\\ 0011 |Safety differential speed (dn 2)| FC36 | R/W | | ||
+ | | 0012 |Calculated torque of the screw| | ||
+ | | 0013 |Temperature reading to the analog input IA2| FC50 | R | | ||
+ | | 0014\\ 0015 |Absolute differential ratio cylinder / screw (long)| | ||
+ | | 0016\\ 0017 |Screw speed| | ||
+ | | 0018\\ 0019 |Cylinder speed| | ||
+ | | 0020 |Couple read to the analog input IA1| FC5E | R | | ||
+ | | 0021 |Torque for screw torque calculation| | ||
+ | | 0022 |Torque differential for predictive calculation| | ||
+ | | 0023 |Couple preditive purposes| | ||
+ | | 0024\\ 0025 |Adjusting differential speed set point| | ||
+ | | 0026 |Inputs state| | ||
+ | | 0027 |Outputs state| | ||
+ | | 0028 | | | | | ||
+ | | 0029 | | | | | ||
+ | | 0030 | | | | | ||
+ | | 0031 | | | | | ||
+ | | 0032 | | | | | ||
+ | |||
+ | ===== - MODBUS settings ===== | ||
+ | |||
+ | The default settings is of the MODBUS/RTU module is: | ||
+ | * Mode = Slave | ||
+ | * Protocol = RTU | ||
+ | * Card Id = 1 | ||
+ | * Baud-rate = Selectable (See the CN2 paragraph) | ||
+ | * Stop-bit = 1 | ||
+ | * Parity = none | ||
+ | * Responce-delay = 5 milliseconds | ||
+ | |||
+ | ^: | ||
+ | |:::| //**Type request**// | ||
+ | |:::| 3 |Read Holding Register| | ||
+ | |:::| 6 |Write Single Holding Register| | ||
+ | |:::| 16 |Write Multiple Holding Register| | ||
+ | ===== - HA548.04 setup data setting ===== | ||
+ | |||
+ | Enter to the HA548.04 setup and to set the following parameters: | ||
+ | |||
+ | ^ Code ^Description^ | ||
+ | | rS |RS 485 Enable| | ||
+ | | br |RS 485 Speed transmission| | ||
+ | | db |Number of the data bits| 8 | | ||
+ | | Sb |Number of the stop bits| 1 | | ||
+ | | PA |Paruty bit| 0 | | ||
+ | | rc |Delay of the character transmission| | ||
+ | | CI |Address code| 1 | | ||
+ | |||
+ | ===== - Diagnostic ===== | ||
+ | |||
+ | The 4 leds L1, L2, L3, L4 shows the diagnostic: | ||
+ | * L1 = Transmission to HA548.04 in progress | ||
+ | * L2 = Receive from the HA548.04 in progress | ||
+ | * L3 = Modbus message in working | ||
+ | * L4 = Configuration error | ||
+ | |||
+ | ^: | ||
+ | |||
+ | ====== - Testing with PC program ====== | ||
+ | |||
+ | To test the modbus functionality on the PC, you must use a program " | ||
+ | You can use the ModScan32 program of WinTech (www.win-tech.com) | ||
+ | |||
+ | ^: | ||
+ | |||
+ | ===== - Setup ModScan32 program ===== | ||
+ | |||
+ | Press to menù Connection → Connect: | ||
+ | |||
+ | * Select the serial port on your PC (eample COM2) | ||
+ | * then in the Configuration section, to set Modbus communication data (Baudrate can be selected as described under CN2) | ||
+ | * then in Protocol Selection, to set the data as in the following picture | ||
+ | |||
+ | {{: | ||
+ | |||
+ | ^: |