1. P1R11FA10 - 001 : User manual

:info:The following table shows the mapping of the MODBUS protocol WORD that you can be read.
All the WORD must be read with the “Holding Registers”.
Modbus
Word
Address
HA548.04 parameter description HA548.04 Address Acces type
R/W
0001 Progressive number of refresh cycles n.d. R
0002 Error numbers of the comunication toward the HA548.04 n.d. R
0003 Co1 Torqe threshold FC28 R/W
0004
0005
Basic differential speed (dn 0) FC2A R/W
0006 Co 2 Torque threshold FC2E R/W
0007
0008
Differential modulation speed (dn 1) FC30 R/W
0009 Co 2 Torque threshold FC34 R/W
0010
0011
Safety differential speed (dn 2) FC36 R/W
0012 Calculated torque of the screw FC4E R
0013 Temperature reading to the analog input IA2 FC50 R
0014
0015
Absolute differential ratio cylinder / screw (long) FC52 R
0016
0017
Screw speed FC56 R
0018
0019
Cylinder speed FC5A R
0020 Couple read to the analog input IA1 FC5E R
0021 Torque for screw torque calculation FC60 R
0022 Torque differential for predictive calculation FC62 R
0023 Couple preditive purposes FC64 R
0024
0025
Adjusting differential speed set point FC66 R
0026 Inputs state FC6A R
0027 Outputs state FC6C R
0028
0029
0030
0031
0032

The default settings is of the MODBUS/RTU module is:

  • Mode = Slave
  • Protocol = RTU
  • Card Id = 1
  • Baud-rate = Selectable (See the CN2 paragraph)
  • Stop-bit = 1
  • Parity = none
  • Responce-delay = 5 milliseconds
:important: Accepted modbus requests
Type request Description
3 Read Holding Register
6 Write Single Holding Register
16 Write Multiple Holding Register

Enter to the HA548.04 setup and to set the following parameters:

Code Description Value
rS RS 485 Enable 1
br RS 485 Speed transmission 9600
db Number of the data bits 8
Sb Number of the stop bits 1
PA Paruty bit 0
rc Delay of the character transmission 5
CI Address code 1

The 4 leds L1, L2, L3, L4 shows the diagnostic:

  • L1 = Transmission to HA548.04 in progress
  • L2 = Receive from the HA548.04 in progress
  • L3 = Modbus message in working
  • L4 = Configuration error
:important:For reset the communication errors, press the RESET button

2. Testing with PC program

To test the modbus functionality on the PC, you must use a program “Modbus RTU Master”.
You can use the ModScan32 program of WinTech (www.win-tech.com)

:todo:Connect properly the USER port (CN2 pins 4A, 5A, 5B) to the serial port of the PC, and then set the dips SW2.1-5 OFF e SW2.6 ON.

Press to menù Connection → Connect:

  • Select the serial port on your PC (eample COM2)
  • then in the Configuration section, to set Modbus communication data (Baudrate can be selected as described under CN2)
  • then in Protocol Selection, to set the data as in the following picture

:tip:Length must not exceed the value of 32, otherwise it must be done a reboot of the instrument.