Differences
This shows you the differences between two versions of the page.
Both sides previous revision Previous revision Next revision | Previous revision | ||
en:strumenti:qmoveplus:j1p20:p1p20f-005:mce_p1p20f-005 [2017/05/11 14:13] – qem103 | en:strumenti:qmoveplus:j1p20:p1p20f-005:mce_p1p20f-005 [2019/08/29 17:01] (current) – external edit 127.0.0.1 | ||
---|---|---|---|
Line 1: | Line 1: | ||
+ | ====== MCE _ P1P20F - 005 : Connections ====== | ||
+ | |||
+ | * **[[# | ||
+ | * **[[# | ||
+ | * **[[# | ||
+ | * **[[# | ||
+ | * **[[# | ||
+ | |||
+ | < | ||
+ | ====== - Informations ====== | ||
+ | |||
+ | ===== - Release ===== | ||
+ | |||
+ | This document is valid except for errors or omissions. | ||
+ | |||
+ | | {{: | ||
+ | ^ Document: | ||
+ | ^ Description: | ||
+ | ^ Editor: | ||
+ | ^ Approver | ||
+ | ^ Link: | http:// | ||
+ | ^ Language: | ||
+ | | |||| | ||
+ | ^ Document Release | ||
+ | | 01 | New manual | ||
+ | |||
+ | ==== - Specifications/ | ||
+ | |||
+ | The copyright to this manual are reserved. For no reason, this document may be copied or reproduced in any form without the QEM permission. | ||
+ | |||
+ | QEM has no assurances or warranties regarding to content. Qem disclaims any responsibility relating to warranties of fitness for any particular purpose. The informations in this document are subject to change without notice. QEM not assumes responsibility for any error that may appear in this document | ||
+ | |||
+ | Trademarks : | ||
+ | |||
+ | * QEM® is a registered trademark. | ||
+ | * Microsoft® and MS-DOS® ar registered trademarks of Windows® and it is a trademark of the Microsoft Corporation. | ||
+ | |||
+ | < | ||
+ | |||
+ | ====== - Description ====== | ||
+ | |||
+ | The **P1P20F - 005**** application, | ||
+ | |||
+ | {{: | ||
+ | |||
+ | |||
+ | ====== - Hardware and connections ====== | ||
+ | ===== - Base card ===== | ||
+ | ==== - Power supply ==== | ||
+ | |||
+ | The instrument must be powered to 24Vdc. No internal fuse will be provided. | ||
+ | |||
+ | ==== - Connectivity ==== | ||
+ | |||
+ | Will be provided in " | ||
+ | nr. 2 serials: | ||
+ | |||
+ | *PROG PORT -> Serial with TTL logic standard for programming. | ||
+ | *ETHERNET PORT | ||
+ | |||
+ | Nr. 1 MMC port to save/load data from external memory. | ||
+ | |||
+ | < | ||
+ | |||
+ | ==== - J1-P20-FZ20 ==== | ||
+ | |||
+ | | {{: | ||
+ | | //Standard film QEM of the J1-P20FZ20// | ||
+ | |||
+ | \\ | ||
+ | \\ | ||
+ | |||
+ | | {{strumenti: | ||
+ | | //Rear view of the J1-P20FZ20// | ||
+ | |||
+ | < | ||
+ | |||
+ | |||
+ | ==== - I/O list ==== | ||
+ | |||
+ | In this section we list all the I/O used and divided by connector. | ||
+ | |||
+ | === - Digital inputs (n. 24) === | ||
+ | |||
+ | * NO = Normally open | ||
+ | * NC = Normally closed | ||
+ | * I = Impulsive | ||
+ | * C = Continuous | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | I1 | **Emergency Push Button** | ||
+ | | I2 | **Manual / Automatic** | ||
+ | | I3 | **Start / Stop** | ||
+ | | I4 | **Stop** | ||
+ | | I5 | **Free** | ||
+ | | I6 | **Restart** | ||
+ | | I7 | **End coil** | ||
+ | | I8 | **Fault drive WEB** | NC | C | ON = Drive OK | ::: | CN6.9 | ::: | | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | I9 | **Fault drive Camme** | ||
+ | | I10 | **Thermal WEB** | NC | C | OFF = Alarm | ::: | CN5.3 | ::: | | ||
+ | | I11 | **Thermal Cams** | ||
+ | | I12 | **Motor Cams Brake** | ||
+ | | I13 | **Anti-static bars** | ||
+ | | I14 | **Anti-jam** | ||
+ | | I15 | **Piece counter block** | ||
+ | | I16 | **Free** | ||
+ | |||
+ | All the inputs of the **CN11** are used as **RESERVES**. | ||
+ | |||
+ | < | ||
+ | === - Digital outputs (n. 24) === | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | O1 |**Tolerance positioning** | ||
+ | | O2 |**End Step** | ||
+ | | O3 |**End Program** | ||
+ | | O4 |**Stop not occurring** | ||
+ | | O5 |**Enabling WEB Drive** | ||
+ | | O6 |**Cams enabling** | ||
+ | | O7 |**Air blow 01** | C | ON = EV active | ||
+ | | O8 |**Air blow 02** | C | ON = EV active | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | O9 | ||
+ | | O10 |**Anti-static bars** | ||
+ | | O11 |**Anti-jam** | ||
+ | | O12 |**Accessory 05** | C | ON = EV active | ||
+ | | O13 |**Accessory 06** | C | ON = EV active | ||
+ | | O14 |**Accessory 07** | C | ON = EV active | ||
+ | | O15 |**Welder 01** | C | ON = EV active | ||
+ | | O16 |**Welder 02** | C | ON = EV active | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | O17 |**Machine OK** | C | ON = no alarms | ||
+ | | O18 |**Red lamp** | ||
+ | | O19 |**Green lamp** | ||
+ | | O20 |**Yellow lamp** | ||
+ | | O21 |**Beep** | ||
+ | | O22 |**Cams motor brake** | ||
+ | | O23 |**Free** | ||
+ | | O24 |**Free** | ||
+ | |||
+ | < | ||
+ | |||
+ | === - Bidirectional counter inputs (n° 2) === | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | PHA1\\ PHB1| **Encoder phases cams axis** | ||
+ | | PHZ1 | **Cam Axis zeroing Sensor** | ||
+ | |||
+ | ^ NAME ^ DESCRIPTION | ||
+ | | PHA2\\ PHB2| **Encoder phases WEB axis** | ||
+ | | PHZ2 | **Photocell** | ||
+ | === - Analog outputs (n° 2) === | ||
+ | |||
+ | ^NAME ^DESCRIPTION | ||
+ | |AO1|**Cams axis drive command ** 0-10 Vdc| CN3.2 |{{: | ||
+ | |AO2|**WEB axis drive command** +/- 10Vdc| CN3.3 |:::|:::| | ||
+ | |||
+ | === - Analog inputs (n° 2) === | ||
+ | |||
+ | ^NAME ^DESCRIPTION | ||
+ | |AI1|**Welder Thermocouple 01**| CN13.3 | ||
+ | |AI2|**Welder Thermocouple 02**| CN13.6 |:::|:::| | ||
+ | |||
+ | < | ||
+ | |||
+ | |||
+ | |||
+ | |||
+ | ===== - Diagnostic ===== | ||
+ | |||
+ | To access the diagnostics section: | ||
+ | |||
+ | * press **MENU** button on the top bar {{: | ||
+ | |||
+ | * Access the diagnostic with the {{: | ||
+ | |||
+ | {{: | ||
+ | |||
+ | From this screen you can access the various diagnostic sections: | ||
+ | |||
+ | * Digital Input Diagnostics | ||
+ | * Digital Output Diagnostics | ||
+ | * Counts Diagnostics | ||
+ | * Analog Output Diagnostics | ||
+ | * Analog Input Diagnostics | ||
+ | |||
+ | < | ||
+ | ==== - Digital Input Diagnostics ==== | ||
+ | |||
+ | Press the digital inputs button to access the following screen, where is showed the status of each input. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | To scroll through the various pages, if present, use the {{: | ||
+ | |||
+ | To return to the diagnostic menu press the {{: | ||
+ | |||
+ | ==== - Digital Output Diagnostics ==== | ||
+ | |||
+ | Pressing the button for the digital outputs will take you to the following screen, where is showed the status of each output. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | To scroll through the various pages, if presents, use the {{: | ||
+ | |||
+ | === - Forcing the outputs === | ||
+ | |||
+ | To access the output forcing function: | ||
+ | |||
+ | * Press top where the page title **DIGITAL OUTPUTS** is showed | ||
+ | |||
+ | * The title changes to **ACTIVE FORCING** and starts blinking -> Active function | ||
+ | |||
+ | * Press the output to activate it. Press again to turn it off. | ||
+ | |||
+ | * Press the title space to turn off the function. | ||
+ | |||
+ | * When the page exits, the function automatically switches off. | ||
+ | |||
+ | To return to the Diagnostics menu press the {{: | ||
+ | |||
+ | < | ||
+ | |||
+ | ==== - Counts Diagnostics ==== | ||
+ | |||
+ | The following screen is accessed by pressing the Counts button. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | To return to the Diagnostics menu press the {{: | ||
+ | |||
+ | ==== - Analog Output Diagnostics ==== | ||
+ | |||
+ | By pressing the button for the analog outputs, the following screen is showed. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | The analog output is expressed in volts. | ||
+ | |||
+ | To return to the Diagnostics menu press the {{: | ||
+ | |||
+ | < | ||
+ | ==== - Digital Input Diagnostics ==== | ||
+ | |||
+ | Press the digital inputs key to access the following screen. | ||
+ | |||
+ | {{: | ||
+ | |||
+ | To return to the Diagnostics menu press the {{: | ||
+ | |||
+ | < | ||
+ | |||
+ | ====== - Assistance ====== | ||
+ | |||
+ | {{page>: |