Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revision Previous revision
Next revision
Previous revision
en:strumenti:qmoveplus:c1r44:p1r44f-001:mdo_p1r44f-009 [2022/12/14 11:04] – [Table] qem215en:strumenti:qmoveplus:c1r44:p1r44f-001:mdo_p1r44f-009 [2022/12/23 15:49] (current) – [Belt] qem215
Line 11: Line 11:
 ^ Editor:                                            | Andrea Zarantonello                                                                                          ||| ^ Editor:                                            | Andrea Zarantonello                                                                                          |||
 ^ Approver                                           | Giuliano Tognon                                                                                              ||| ^ Approver                                           | Giuliano Tognon                                                                                              |||
-^ Link:                                              | http://www.qem.eu/doku/doku.php/en/strumenti/qmoveplus/c1r44/p1r44f-001/mdo_p1r44f-009                       |||+^ Link:                                              | https://www.qem.eu/doku/doku.php/en/strumenti/qmoveplus/c1r44/p1r44f-001/mdo_p1r44f-009                       |||
 ^ Language:                                          | English                                                                                                      ||| ^ Language:                                          | English                                                                                                      |||
 |                                                                                                                                                                  |||| |                                                                                                                                                                  ||||
Line 39: Line 39:
  
    *Bridge axis positioner, with "S" ramps    *Bridge axis positioner, with "S" ramps
-   *Belt positioner+   *Belt analogic command
    *Heads ascent/descent, according to the speed of the belt    *Heads ascent/descent, according to the speed of the belt
    *Control of 22 polishing heads    *Control of 22 polishing heads
Line 139: Line 139:
 | {{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:buttons:butt_motor_120x60_off.png?100&nolink}}          | Access to the engine test page.                                                            | | {{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:buttons:butt_motor_120x60_off.png?100&nolink}}          | Access to the engine test page.                                                            |
 | {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:belt_page.png?100&nolink}}                                   | Access to the belt speed setting page                                                      | | {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:belt_page.png?100&nolink}}                                   | Access to the belt speed setting page                                                      |
 +| {{:strumenti:qmoveplus:c1r44:p1r44f-001:enable_disable_page_button.png?100&nolink}}                     | Access to enable/disable heads page                                                        |
 | {{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:buttons:butt_belt_60x60_off.png?50&nolink}}             | Forcing the movement of the conveyor belt and the conveyor rollers (only in manual mode).  | | {{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:buttons:butt_belt_60x60_off.png?50&nolink}}             | Forcing the movement of the conveyor belt and the conveyor rollers (only in manual mode).  |
  
Line 183: Line 184:
 | Air pressure                             | Input from pressure switch (I05) deactivated or insufficient air pressure                                                                                                         | Check pressure switch or connections                                                  | | Air pressure                             | Input from pressure switch (I05) deactivated or insufficient air pressure                                                                                                         | Check pressure switch or connections                                                  |
 | Thermal overload                         | Input (I01) from one of the thermal switches off                                                                                                                                  | Check switches and wiring                                                             | | Thermal overload                         | Input (I01) from one of the thermal switches off                                                                                                                                  | Check switches and wiring                                                             |
-| Bridge inverter KO                       | Bridge inverter malfunction (I02 Off)                                                                                                                                             | Check inverter or wiring                                                              | +| Bridge inverter fault                    | Bridge inverter malfunction (I02 Off)                                                                                                                                             | Check inverter or wiring                                                              | 
-| Belt inverter KO                         | Conveyor belt inverter Malfunction (I03 Off)                                                                                                                                      | Check Inverter or Wiring                                                              | +| Belt inverter fault                      | Conveyor belt inverter Malfunction (I03 Off)                                                                                                                                      | Check Inverter or Wiring                                                              | 
-| Roller inverter KO                       | Roller conveyor inverter malfunction (I04 Off)                                                                                                                                    | Check inverter or wiring                                                              |+| Roller inverter fault                    | Roller conveyor inverter malfunction (I04 Off)                                                                                                                                    | Check inverter or wiring                                                              |
 | Emergency button pressed                 | Emergency button (I13) pressed                                                                                                                                                    | Unlock button or check wiring                                                         | | Emergency button pressed                 | Emergency button (I13) pressed                                                                                                                                                    | Unlock button or check wiring                                                         |
 | CANBUS communication error (RMC3M-DD)    | Error in communication with node 1 of the CANOPEN network. Node 1 is represented by the RMC3M-DD I / O module which manages the outputs relating to the heads.                    | Remove and restore power to the system. If this is not enough, check the bus wiring.  | | CANBUS communication error (RMC3M-DD)    | Error in communication with node 1 of the CANOPEN network. Node 1 is represented by the RMC3M-DD I / O module which manages the outputs relating to the heads.                    | Remove and restore power to the system. If this is not enough, check the bus wiring.  |
Line 210: Line 211:
  
 {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:horizontal_en.png?nolink&600|}} {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:horizontal_en.png?nolink&600|}}
-^ // ** Parameter ** // ^ // ** Unit of measure ** // ^ // ** Range ** // ^ // ** Description ** // ^ +^ // ** Parameter ** //              ^ // ** Unit of measure ** //  ^ // ** Range ** //  ^ // ** Description ** //                                                                                                                                                                           
-| Head correction \\ (on the left) | mm | -9999.9 ÷ 9999.9 | Early (positive value) or delay (negative value) space compared to the start of the piece, use it to anticipate / postpone the activation of the head. | +| Head correction \\ (on the left)   | mm                           | -9999.9 ÷ 9999.9   | Early (positive value) or delay (negative value) space compared to the start of the piece, use it to anticipate / postpone the activation of the head.                                            
-| Tail correction \\ (on the right) | mm | -9999.9 ÷ 9999.9 | Early (positive value) or delay (negative value) space compared to the end of the piece, use it to anticipate / postpone the deactivation of the head. | +| Tail correction \\ (on the right)  | mm                           | -9999.9 ÷ 9999.9   | Early (positive value) or delay (negative value) space compared to the end of the piece, use it to anticipate / postpone the deactivation of the head.                                            | 
-| Reference speed | mm | 0 ÷ 99999.9 | Speed of the bridge which the correction values refer. \\ As the speed changes, the correction values vary proportionally. \\ With value = 0 the correction values remain constant at any speed. |+| Bridge speed                       | m / '                        | 0 ÷ 999.9          | Actual speed of the bridge                                                                                                                                                                        
 +| Reference speed                                           | 0 ÷ 999.9          | Speed of the bridge which the correction values refer. \\ As the speed changes, the correction values vary proportionally. \\ With value = 0 the correction values remain constant at any speed.  |
  
 Look in the [[en/strumenti:qmoveplus:c1r44:p1r44f-001:mmf_p1r44f-009|start up manual]] how to best perform the procedures. Look in the [[en/strumenti:qmoveplus:c1r44:p1r44f-001:mmf_p1r44f-009|start up manual]] how to best perform the procedures.
-<html><pagebreak /></html>+ 
 +The button {{:strumenti:qmoveplus:c1r44:p1r44f-001:offset_button.png?nolink&100|}} open the page "Offset tools": 
 + 
 +{{:strumenti:qmoveplus:c1r44:p1r44f-001:offset_teste.png?nolink&500|}} 
 + 
 +In this page is possible to set a horizontal offset for every single head.\\ The button =0 reset all the offset values \\ The button "progression" associate to every head the value "progression of" + offset of the head before.  
 ==== Orthogonal correction==== ==== Orthogonal correction====
 Look image [[#Functioning| general view machine]] Look image [[#Functioning| general view machine]]
Line 222: Line 229:
 {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:orthogonal_en.png?nolink&600|}} {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:orthogonal_en.png?nolink&600|}}
  
-^ // ** Parameter ** // ^ // ** Unit of measure ** // ^ // ** Range ** // ^ // ** Description ** // ^ +^ // ** Parameter ** //       ^ // ** Unit of measure ** //  ^ // ** Range ** //  ^ // ** Description ** //                                                                                                                                                                
-| Correction IN \\ (top) | mm | -9999.9 ÷ 9999.9 | Early (positive value) or delay (negative value) compared to the leading edge of the piece, with which to anticipate / postpone the activation of the head. | +| Correction IN \\ (top)      | mm                           | -9999.9 ÷ 9999.9   | Early (positive value) or delay (negative value) compared to the leading edge of the piece, with which to anticipate / postpone the activation of the head.                            
-| Correction OUT \\ (bottom) | mm | -9999.9 ÷ 9999.9 | Advance space (negative value) or delay (positive value) compared to the outgoing edge of the piece, with which to anticipate / postpone the deactivation of the head. | +| Correction OUT \\ (bottom)  | mm                           | -9999.9 ÷ 9999.9   | Advance space (negative value) or delay (positive value) compared to the outgoing edge of the piece, with which to anticipate / postpone the deactivation of the head.                 | 
-| Reference speed | mm | 0 ÷ 99999.9 | Speed to which the correction values refer. \\ As the speed changes, the correction values vary proportionally. \\ With value = 0 the correction values remain constant at any speed. |+| Bridge speed                | m / '                        | 0 ÷ 999.9          | Actual speed of the bridge                                                                                                                                                             
 +| Reference speed                                    | 0 ÷ 999.9          | Speed to which the correction values refer. \\ As the speed changes, the correction values vary proportionally. \\ With value = 0 the correction values remain constant at any speed.  |
  
 Look in the [[strumenti:qmoveplus:c1r44:p1r44f-001:mmf_p1r44f-009|commissioning manual]] how to best perform the procedures. Look in the [[strumenti:qmoveplus:c1r44:p1r44f-001:mmf_p1r44f-009|commissioning manual]] how to best perform the procedures.
Line 408: Line 416:
 <html><pagebreak /></html> <html><pagebreak /></html>
 ===== Motors ===== ===== Motors =====
-{{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:buttons:butt_motor_120x60_off.png?nolink&100}} -> {{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:pages:p_engines.png?nolink&500}}+{{:strumenti:qmoveplus:c1r11:mdu_p1r11fb30-001Q:buttons:butt_motor_120x60_off.png?nolink&100}} -> {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:engines_1.png?nolink&400|}} {{:en:strumenti:qmoveplus:c1r44:p1r44f-001:engines_2.png?nolink&400|}}
  
-In this page it is possible to force the activation outputs of the head's motors. It required to be in manual mode.\\ To do this, press on the key with the number of the head you want to activate. The led indicates the status.+In this page it is possible to force the activation outputs of the head's motors, the descent and ascent of the heads. It required to be in manual mode.\\ To do this, press on the key with the number of the head you want to activate. The led indicates the status. If 
  
 <html><pagebreak /></html> <html><pagebreak /></html>
Line 418: Line 426:
  
 In this page it is possible to set the speed of the conveyor belt. Max and min values are setted in generic parameters (PG 36  PG 37). In this page it is possible to set the speed of the conveyor belt. Max and min values are setted in generic parameters (PG 36  PG 37).
 +If the machine is in **MANUAL** state:\\  press button {{:strumenti:qmoveplus:c1r44:p1r44f-001:pulsante_rulliere.png?nolink&50|}}  to activate O3: ROLLERS RUN, \\ press button{{:en:strumenti:qmoveplus:c1r44:p1r44f-001:belt_page.png?nolink&90|}} to activate O2 "BELT RUN"
 +<html><pagebreak /></html>
 +
 +===== Enable/Disable Tools =====
 +{{:strumenti:qmoveplus:c1r44:p1r44f-001:enable_disable_page_button.png?100&nolink}} -> {{:strumenti:qmoveplus:c1r44:p1r44f-001:enable_head_page.png?nolink&400|}}
 +
 +In this page it's possible to enable or disable the tools.\\ Led on (yellow) = tool enabled\\ Led off(grey) = tool disabled 
  
 <html><pagebreak /></html> <html><pagebreak /></html>
  • Last modified: 2022/12/14 11:04