The values given in the table refer to input signals A, B and Z.
The max. frequency given in the table refers to A and B phase signals with a DutyCycle = 50%
With count frequencies over 50KHz the use of Line-Driver type encoders is recommended.
Push-Pull
| Type of polarisation | PNP/PP |
| Max frequency | 200KHz |
| Min. acquisition time | 5µs |
| Insulation | 1000Vrms |
| Rated operating voltage | 24Vdc |
| Voltage of logic status 0 | 0 - 2 V |
| Voltage of logic status 1 | 10.5 - 26.5 V |
| Internal voltage drop | 1.2V |
| Input resistance | 3100Ω |
Line-Driver
| Type of polarisation | Line-Driver |
| Max. frequency | 200KHz |
| Min. acquisition time | 5µs |
| Insulation | 1000Vrms |
| Rated operating voltage (PHx+ ? PHx-) | 5Vdc |
| Voltage of logic status 0 (PHx+ ? PHx-) | 0-1.5 V |
| Voltage of logic status 1 (PHx+ ? PHx-) | 2-5 V |
| Internal voltage drop | 1.2V |
| Input restistance | 150Ω |