The electrical features are given in section Electrical features. The example of the connection are given in section Connection examples |
---|
CN23 | Terminal | Simbol | Description | Address | |
---|---|---|---|---|---|
1A | VD1 | Internal bridge 1A -1B | |||
2A | DIR1+ | DIRECTION 1 output | Push-Pull Line Driver | 3.PULSE01 | |
3A | STEP1+ | STEP 1 output | |||
4A | DIR2+ | DIRECTION 2 output | 3.PULSE02 | ||
5A | STEP2+ | STEP 2 output | |||
6A | 0V | Stepper outputs common | |||
1B | VD1 | Internal bridge 1A -1B | |||
2B | DIR1- | DIRECTION 1 complementary output | Complementary outputs for use on driver with Line-Driver inputs | ||
3B | STEP1- | STEP 1 complementary output | |||
4B | DIR2- | DIRECTION 2 complementary output | |||
5B | STEP2- | STEP 2 complementary output | |||
6B | 0V | Stepper outputs common |
CN24 | Terminal | Simbol | Description | Address | |
---|---|---|---|---|---|
1A | VD2 | Internal bridge 1A -1B | |||
2A | DIR3+ | DIRECTION 3 output | Push-Pull Line Driver | 3.PULSE03 | |
3A | STEP3+ | STEP 3 output | |||
4A | DIR4+ | DIRECTION 4 output | 3.PULSE04 | ||
5A | STEP4+ | STEP 4 output | |||
6A | 0V | Stepper outputs common | |||
1B | VD2 | Internal bridge 1A -1B | |||
2B | DIR3- | DIRECTION 3 complementary output | Complementary outputs for use on driver with Line-Driver inputs | ||
3B | STEP3- | STEP 3 complementary output | |||
4B | DIR4- | DIRECTION 4 complementary output | |||
5B | STEP4- | STEP 4 complementary output | |||
6B | 0V | Stepper outputs common |
CN25 | Terminal | Simbol | Description | Address | |
---|---|---|---|---|---|
1A | VD3 | Internal bridge 1A -1B | |||
2A | DIR5+ | DIRECTION 5 output | Push-Pull Line Driver | 3.PULSE05 | |
3A | STEP5+ | STEP 5 output | |||
4A | - | n.c. | |||
5A | - | n.c. | |||
6A | 0V | Stepper outputs common | |||
1B | VD3 | Internal bridge 1A -1B | |||
2B | DIR5- | DIRECTION 5 complementary output | Complementary outputs for use on driver with Line-Driver inputs | ||
3B | STEP5- | STEP 5 complementary output | |||
4B | - | n.c. | |||
5B | - | n.c. | |||
6B | 0V | Stepper outputs common |
STEP-DIRECTION voltage settings
With JP1 to JP9 jumper, you can set the nominal voltage of the STEP and DIR outputs.
For each connector should be inserted only one bridge at a time If you select one of the two voltages 5V(JP3,JP6,JP9) or 12V(JP1,JP4,JP7) the 1A and 1B terminals must be disconnected |
---|
.