en:lib:mdl:mdl-h-cnstep-050

This translation is older than the original page and might be outdated. See what has changed.
:tip:The electrical features are given in section Electrical features.
The example of the connection are given in section Connection examples
CN23 TerminalSimbolDescriptionAddress
1A VD1 Internal bridge 1A -1B
2A DIR1+ DIRECTION 1 outputPush-Pull Line Driver3.PULSE01
3A STEP1+ STEP 1 output
4A DIR2+ DIRECTION 2 output 3.PULSE02
5A STEP2+ STEP 2 output
6A 0V Stepper outputs common
1B VD1 Internal bridge 1A -1B
2B DIR1- DIRECTION 1 complementary outputComplementary outputs for use
on driver with Line-Driver inputs
3B STEP1- STEP 1 complementary output
4B DIR2- DIRECTION 2 complementary output
5B STEP2- STEP 2 complementary output
6B 0V Stepper outputs common
CN24 TerminalSimbolDescriptionAddress
1A VD2 Internal bridge 1A -1B
2A DIR3+ DIRECTION 3 outputPush-Pull Line Driver3.PULSE03
3A STEP3+ STEP 3 output
4A DIR4+ DIRECTION 4 output 3.PULSE04
5A STEP4+ STEP 4 output
6A 0V Stepper outputs common
1B VD2 Internal bridge 1A -1B
2B DIR3- DIRECTION 3 complementary outputComplementary outputs for use
on driver with Line-Driver inputs
3B STEP3- STEP 3 complementary output
4B DIR4- DIRECTION 4 complementary output
5B STEP4- STEP 4 complementary output
6B 0V Stepper outputs common
CN25 TerminalSimbolDescriptionAddress
1A VD3 Internal bridge 1A -1B
2A DIR5+ DIRECTION 5 outputPush-Pull Line Driver3.PULSE05
3A STEP5+ STEP 5 output
4A - n.c.
5A - n.c.
6A 0V Stepper outputs common
1B VD3 Internal bridge 1A -1B
2B DIR5- DIRECTION 5 complementary outputComplementary outputs for use
on driver with Line-Driver inputs
3B STEP5- STEP 5 complementary output
4B - n.c.
5B - n.c.
6B 0V Stepper outputs common

STEP-DIRECTION voltage settings

With JP1 to JP9 jumper, you can set the nominal voltage of the STEP and DIR outputs.

:important:For each connector should be inserted only one bridge at a time
If you select one of the two voltages 5V(JP3,JP6,JP9) or 12V(JP1,JP4,JP7) the 1A and 1B terminals must be disconnected

.

Name
jumper
Setting Nominal voltage
JP1 INSERTED 12V (voltage supplied by the device)
JP2 INSERTED VD1 (Voltage to be supplied to terminals 1A or 1B)
JP3 INSERTED 5V (Voltage supplied by the device)
JP4 INSERTED 12V (voltage supplied by the device)
JP5 INSERTED VD2 (Voltage to be supplied to terminals 1A or 1B)
JP6 INSERTED 5V (Voltage supplied by the device)
JP7 INSERTED 12V (voltage supplied by the device)
JP8 INSERTED VD3 (Voltage to be supplied to terminals 1A or 1B)
JP9 INSERTED 5V (Voltage supplied by the device)
JP1,JP4,JP7
JP2,JP5,JP8
JP3,JP6,JP9