| SW1 | Dip | DIP Settings | Function | |||
|---|---|---|---|---|---|---|
| 1 | OFF | Baud-rate 57600 | PROG PORT transmission speed selection | ||
| ON | Baud-rate 115200 | |||||
| 2 | OFF | Baud-rate 57600 | USER PORT transmission speed selection | |||
| ON | Baud-rate 115200 | |||||
| 3 | OFF | Can also be used by SERCOM and MODBUS device | PROG PORT function mode selection | |||
| ON | Cannot be used by SERCOM and MODBUS device | |||||
| 4 | OFF | ON | OFF | ON | Valid if in the CANOPEN device declaration is set the speed to 0 )] | |
| 5 | OFF | OFF | ON | ON | ||
| Baud-rate 125KB/S | Baud-rate 250KB/S | Baud-rate 500KB/S | Baud-rate 1MB/S |
|||
| 6 | OFF | MMC/SD | External media device selection on the system functions | |||
| ON | USB | |||||
| 7 | Reserved. Leave OFF | |||||
| 8 | OFF | PROG PORT normal | Select the USER PORT as PROG PORT1) | |||
| ON | PROG PORT on the USER PORT connector | |||||
1)
It's possible to use the connector of the USER PORT as PROG PORT with RS232 electric standard. The mini-USB PROG PORT connector is unplugged (USER PORT electric standard setting). For this function is necessary to set at OFF the dip 6 of the SW2.