en:software:qview:qview_6:ladder_library:20004

This translation is older than the original page and might be outdated. See what has changed.
Function name SDCOMNQ_010
Function version 1.0
Function state OBSOLETA
Compatibility with IEC61131-3 not compatible

Graphic symbol :

Input / Output :

Name Belonging Group Access Types of data Description
ON Left Power Flow Activation command sending on slope front
Name Device name Name of the device
Command Device command Command of the device
Condition Normal R , RW F , B , W , L , S Condition to pass in Q
not Q Right Power Flow Resulting state of the negated function elaboration

Description :

The function block SD_COM_NQ is used to send a command to the desired device.


  • Last modified: 2019/08/29 17:01