Function name CLRB_010
Function version 1.0
Function state stable
Compatibility with IEC61131-3 not compatible

Graphic symbol :

Input / Output :

Name Belonging Group Access Types of data Description
EN Left Power Flow IEC1131-3 enable input
Data Normal RW F , B , W , L Data in which to cancel the bit
Bit Normal R , RW F , B , W , L Data with the number of the bit to cancel
ENO Right Power Flow IEC1131-3 enable output

Description :

The function Bit Clear, combines through AND the corresponding bits of the variable Data with the bit of the variable maschera and load the result of a bit in the variable Data.
Where the variable maschera is: maschera = logic NOT with (2 Bit) bits
Error conditions that set ENO = 0: none.